| ABHP |
OVERALL LENGTH |
6.312 INCHES MAXIMUM |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
1.120 INCHES NOMINAL |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.209 INCHES NOMINAL |
| AXGY |
MOUNTING METHOD |
BASE AND UNTHREADED HOLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
LIQUID |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
MOISTURE RESISTANT AND VIBRATION RESISTANT |
| AKBY |
TEMP SENSING ELEMENT TYPE |
IMMERSION WELL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| ABKW |
OVERALL HEIGHT |
2.450 INCHES NOMINAL |
| STYL |
STYLE DESIGNATOR |
RECTANGULAR |
| CTYX |
CONTACT STIMULUS RATING |
132.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 122.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CTYM |
CONTACT ADJUSTMENT RANGE |
+84.00/+132.00 ACTUATION POINT DEGREES FAHRENHEIT AND +84.00/+132.00 DEACTUATION POINT DEGREES FAHRENHEIT |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| AWTN |
OPERATING TEMP RATING |
32.0 DEG FAHRENHEIT MINIMUM AND 132.0 DEG FAHRENHEIT MAXIMUM |