5930-01-276-8099 ( P24236-014-02 , 5-10010 )

NSN Information
NSN FSC NIIN Item Name INC
5930-01-276-8099 5930 012768099 SWITCH,THERMOSTATIC 0045
NSN Features
MRC Parameter Characteristics
CTYX CONTACT STIMULUS RATING 88.00 ACTUATION POINT NOMINAL DEGREES CELSIUS AND 79.00 DEACTUATION POINT NOMINAL DEGREES CELSIUS
AGAV END ITEM IDENTIFICATION 1270-01-142-2855 TARGET DESIGNATOR
CTZB CONTACT VOLTAGE RATING IN VOLTS 20.0 AC AT SEA LEVEL FIRST VOLTAGE
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 AC AT SEA LEVEL SECOND VOLTAGE
AWTN OPERATING TEMP RATING -55.0 DEG CELSIUS MINIMUM AND 150.0 DEG CELSIUS MAXIMUM
ABPM BODY DIAMETER 0.078 INCHES MINIMUM AND 0.108 INCHES MAXIMUM
AXGY MOUNTING METHOD CLAMP
CSCF TERMINAL TYPE WIRE LEAD
CQGB CONTACT ACTION STIMULUS INCREASE
MEDA MEDIA FOR WHICH DESIGNED GAS OR LIQUID
CRLD NONPILE-UP CONTACT ARRANGEMENT 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION
CTYC CONTACT ADJUSTABILITY ACTUATION POINT NOT ADJUSTABLE
AKBY TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
STYL STYLE DESIGNATOR CYLINDRICAL
CBBL FEATURES PROVIDED HERMETICALLY SEALED CASE
CTHF CONTACT LOAD CURRENT RATING 50.0 MILLIAMPERES RESISTIVE LOAD FIRST VOLTAGE
ADAQ BODY LENGTH 0.620 INCHES NOMINAL
ADAV OVERALL DIAMETER 0.078 INCHES MINIMUM AND 0.108 INCHES MAXIMUM
CTHF CONTACT LOAD CURRENT RATING 15.0 MILLIAMPERES RESISTIVE LOAD SECOND VOLTAGE
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
P24236-014-02 58260 F 9 3 A TX
5-10010 18509 A 2 5 5 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
P24236-014-02 58260 PROGRAM MANAGER ADVANCED ATTACK A F
5-10010 18509 PSG CONTROLS INC. A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A X B 3 04/13/1 P 9032100000 0045
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DA Z Q2200X- A
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
B A P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DA SMS Z 0 EA 0 U Z Q2200X- A
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI