| ABXD |
BUSHING LENGTH |
0.463 INCHES MINIMUM AND 0.473 INCHES MAXIMUM |
| CQJX |
NOMINAL THREAD SIZE |
0.469 INCHES |
| ABKW |
OVERALL HEIGHT |
2.863 INCHES MAXIMUM |
| AAQL |
BODY STYLE |
BUSHING MOUNT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ADAT |
BODY WIDTH |
0.880 INCHES MAXIMUM |
| CXQR |
CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.000 AMPERES RESISTIVE DC AND 500.000 MILLIAMPERES INDUCTIVE DC |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
6 POLE, DOUBLE THROW, ONE POSITION MOMENTARY SINGLE SWITCH UNIT |
| AFUX |
ACTUATOR POSITION-ACTION RELATIONSHIP |
DOWN POSITION MAINTAINED AND UP POSITION MAINTAINED AND CENTER POSITION MOMENTARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNS |
| AFUY |
ACTUATOR POSITION-LOCKING RELATIONSHIP |
UP POSITION NO LOCKING ACTION AND DOWN POSITION LOCKED IN AND CENTER POSITION NO LOCKING ACTION |
| AFUR |
ACTUATOR DIAMETER |
0.400 INCHES MINIMUM AND 0.440 INCHES MAXIMUM |
| TTQY |
TERMINAL TYPE AND QUANTITY |
18 TURRET |
| ABHP |
OVERALL LENGTH |
1.200 INCHES MAXIMUM |
| AJWX |
MOUNTING SURFACE TO TERMINAL END DISTANCE |
1.250 INCHES MAXIMUM |
| AFUS |
ACTUATOR HEIGHT |
1.140 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
1.200 INCHES MAXIMUM |
| AFXE |
MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC |
| AAJD |
THREAD CLASS |
2A |
| AFUQ |
ACTUATOR STYLE |
ROUND |
| ABMK |
OVERALL WIDTH |
0.888 INCHES MAXIMUM |
| CMLP |
THREAD QUANTITY PER INCH |
32 |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
SHOCK RESISTANT AND VIBRATION RESISTANT |