| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| ABKV |
OUTSIDE DIAMETER |
0.438 INCHES NOMINAL SINGLE CONNECTION |
| CTYX |
CONTACT STIMULUS RATING |
3100.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH GAGE AND 3000.00 ACTUATION POINT MINIMUM POUNDS PER SQUARE INCH GAGE AND 2700.00 DEACTUATION POINT MINIMUM POUNDS PER SQUARE INCH GAGE AND 2800.00 DEACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH GAGE |
| CQJX |
NOMINAL THREAD SIZE |
0.4375 INCHES SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
3.490 INCHES NOMINAL |
| ADAV |
OVERALL DIAMETER |
1.000 INCHES MAXIMUM |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
FUNGUS RESISTANT AND SALT SPRAY PROOF |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| CTHF |
CONTACT LOAD CURRENT RATING |
2.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CQJB |
PROOF PRESSURE |
6200.00 POUNDS PER SQUARE INCH |
| AXGY |
MOUNTING METHOD |
INPUT PORT |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| ASDB |
WIDTH ACROSS FLATS |
0.870 INCHES MINIMUM AND 0.880 INCHES MAXIMUM |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE PRESSURE CONNECTION |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS |