| FEAT |
SPECIAL FEATURES |
SWITCH UNIT IS NOT IGNITION PROTECTED AND CAN CAUSE SPARKS. EXPLOSION AND DEATH CAN OCCUR. DO NOT INSTALL WHERE FLAMMABLE VAPORS ARE PRESENT |
| AXGY |
MOUNTING METHOD |
BRACKET AND UNTHREADED HOLE |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTYX |
CONTACT STIMULUS RATING |
2.00 ACTUATION POINT NOMINAL INCHES OF WATER AND 0.50 DEACTUATION POINT NOMINAL INCHES OF WATER |
| MEDA |
MEDIA FOR WHICH DESIGNED |
LIQUID |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.156 INCHES NOMINAL |
| CSCF |
TERMINAL TYPE |
WIRE LEAD |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| CTHF |
CONTACT LOAD CURRENT RATING |
10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| ABPM |
BODY DIAMETER |
3.375 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
6.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| ABKW |
OVERALL HEIGHT |
3.125 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
32.0 DC AT SEA LEVEL SECOND VOLTAGE |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL W/PORT |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |