| CTYX |
CONTACT STIMULUS RATING |
260.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 230.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| ADAQ |
BODY LENGTH |
0.290 INCHES NOMINAL |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| AKBY |
TEMP SENSING ELEMENT TYPE |
DISC |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-S-24236/19 GOVERNMENT SPECIFICATION |
| CSCF |
TERMINAL TYPE |
TAB, SOLDER LUG |
| AAJD |
THREAD CLASS |
2A SINGLE THREADED BUSHING |
| CTHF |
CONTACT LOAD CURRENT RATING |
1.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE |
| AXGY |
MOUNTING METHOD |
THREADED BUSHING |
| STYL |
STYLE DESIGNATOR |
PLUG |
| CQGB |
CONTACT ACTION STIMULUS |
DECREASE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE THREADED BUSHING |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-S-24236 SPECIFICATION |
| ASDB |
WIDTH ACROSS FLATS |
0.215 INCHES NOMINAL |
| CTHF |
CONTACT LOAD CURRENT RATING |
1.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE |
| CQJX |
NOMINAL THREAD SIZE |
0.112 INCHES SINGLE THREADED BUSHING |
| CMLP |
THREAD QUANTITY PER INCH |
40 SINGLE THREADED BUSHING |
| ABHP |
OVERALL LENGTH |
0.455 INCHES NOMINAL |
| AWTN |
OPERATING TEMP RATING |
-30.0 DEG FAHRENHEIT MINIMUM AND 400.0 DEG FAHRENHEIT MAXIMUM |