| AXGY |
MOUNTING METHOD |
BRACKET |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
115.0 AC AT SEA LEVEL FIRST VOLTAGE |
| CTHF |
CONTACT LOAD CURRENT RATING |
5.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 2.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 1.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE AND 2.5 AMPERES INDUCTIVE LOAD SECOND VOLTAGE AND 1.0 AMPERES LAMP LOAD SECOND VOLTAGE |
| FREQ |
FREQUENCY IN HERTZ |
60.0 FIRST VOLTAGE |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 500.0 DEG FAHRENHEIT MAXIMUM |
| CSCF |
TERMINAL TYPE |
TAB, SOLDER LUG |
| ABPM |
BODY DIAMETER |
0.540 INCHES MINIMUM AND 0.640 INCHES MAXIMUM |
| CTYX |
CONTACT STIMULUS RATING |
265.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 230.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SECOND VOLTAGE |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-S-24236/1 GOVERNMENT SPECIFICATION |
| AEJN |
DISTANCE BETWEEN MOUNTING FACILITY CENTERS |
0.937 INCHES NOMINAL |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| CTHF |
CONTACT LOAD CURRENT RATING |
0.5 AMPERES LAMP LOAD FIRST VOLTAGE |
| AKBY |
TEMP SENSING ELEMENT TYPE |
INTERNAL SENSOR |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-S-24236 SPECIFICATION |
| ABKW |
OVERALL HEIGHT |
0.526 INCHES MAXIMUM |
| CTYC |
CONTACT ADJUSTABILITY |
ACTUATION POINT NOT ADJUSTABLE AND DEACTUATION POINT NOT ADJUSTABLE |
| CQYJ |
MOUNTING FACILITY PATTERN |
TWO POSITION IN-LINE |
| ABHP |
OVERALL LENGTH |
1.160 INCHES MINIMUM AND 1.260 INCHES MAXIMUM |
| ADAU |
BODY HEIGHT |
0.296 INCHES MINIMUM AND 0.421 INCHES MAXIMUM |
| STYL |
STYLE DESIGNATOR |
DISC W/FLANGE |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, BOTH POSITIONS MAINTAINED |