5930-01-470-9596 ( ADPDC2T04AC )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5930-01-470-9596 | 5930 | 014709596 | SWITCH,SENSITIVE | 0039 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL |
| AKNA | INCLOSURE TYPE | FULLY INCLOSED |
| AAQL | BODY STYLE | HOLE MOUNTED |
| CRRM | SWITCH RELEASE FORCE | 1.0 OUNCES MINIMUM |
| ADAT | BODY WIDTH | 0.640 INCHES NOMINAL |
| CXQR | CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.000 AMPERES RESISTIVE AC |
| AFUR | ACTUATOR DIAMETER | 0.309 INCHES NOMINAL |
| ADAQ | BODY LENGTH | 1.810 INCHES NOMINAL |
| CXQQ | ACTUATOR MOVEMENT | 0.312 PRETRAVEL INCHES MAXIMUM AND 0.187 OVERTRAVEL INCHES NOMINAL AND 0.062 DIFFERENTIAL INCHES MAXIMUM |
| CSJN | SWITCH ACTUATING FORCE | 6.0 OUNCES MAXIMUM |
| AFUS | ACTUATOR HEIGHT | 0.165 INCHES NOMINAL |
| AFUQ | ACTUATOR STYLE | ROUND |
| AFXE | MAXIMUM VOLTAGE RATING IN VOLTS | 250.0 AC |
| AFUU | ACTUATOR FREE POSITION HEIGHT | 0.285 INCHES NOMINAL |
| ADAU | BODY HEIGHT | 0.640 INCHES NOMINAL |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.140 INCHES NOMINAL |
| AXGY | MOUNTING METHOD | UNTHREADED HOLE |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| ADPDC2T04AC | 80207 | F | 9 | 3 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| ADPDC2T04AC | 80207 | C AND K COMPONENTS INC | A | F |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 1 | 01/18/2 | A | P | 8536509050 | 0039 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | N | I | |||
| DF | N | SF9---N | F |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | P | 0 | X | A |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | J | 1 | EA | 0 | U | D | ||
| DF | SMS | J | 1 | EA | 0 | U | SF9---N | F |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|