| CTZL |
PRESSURE CONNECTOR TYPE |
FLARED, THREADED EXTERNAL SINGLE CONNECTION |
| THSD |
THREAD SERIES DESIGNATOR |
UNJF SINGLE PRESSURE CONNECTION |
| ADAQ |
BODY LENGTH |
2.800 INCHES NOMINAL |
| CQJX |
NOMINAL THREAD SIZE |
0.4375 INCHES SINGLE PRESSURE CONNECTION |
| ABHP |
OVERALL LENGTH |
3.750 INCHES MAXIMUM |
| ABKV |
OUTSIDE DIAMETER |
1.000 INCHES NOMINAL SINGLE CONNECTION |
| CSCC |
SENSING ELEMENT BURST PRESSURE |
7500.00 POUNDS PER SQUARE INCH |
| AWTN |
OPERATING TEMP RATING |
-65.0 DEG FAHRENHEIT MINIMUM AND 275.0 DEG FAHRENHEIT MAXIMUM |
| CTYC |
CONTACT ADJUSTABILITY |
DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
| CTZB |
CONTACT VOLTAGE RATING IN VOLTS |
28.0 DC AT SEA LEVEL SINGLE VOLTAGE |
| CTYX |
CONTACT STIMULUS RATING |
2400.00 ACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH AND 2000.00 DEACTUATION POINT MAXIMUM POUNDS PER SQUARE INCH |
| AXGY |
MOUNTING METHOD |
CLAMP |
| CQGB |
CONTACT ACTION STIMULUS |
INCREASE |
| MEDA |
MEDIA FOR WHICH DESIGNED |
GAS OR LIQUID |
| AAJD |
THREAD CLASS |
3A SINGLE PRESSURE CONNECTION |
| CQJB |
PROOF PRESSURE |
4500.00 POUNDS PER SQUARE INCH |
| STYL |
STYLE DESIGNATOR |
CYLINDRICAL |
| CRLD |
NONPILE-UP CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CSCF |
TERMINAL TYPE |
CONNECTOR, RECEPTACLE |
| CTHF |
CONTACT LOAD CURRENT RATING |
3.0 AMPERES INDUCTIVE LOAD SINGLE VOLTAGE AND 4.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE AND 400.0 MILLIAMPERES LAMP LOAD SINGLE VOLTAGE |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
DUSTPROOF |
| ASDB |
WIDTH ACROSS FLATS |
1.185 INCHES NOMINAL |
| AJZC |
PRESSURE SWITCH TYPE |
GAGE |
| CBBL |
FEATURES PROVIDED |
ELECTRICAL BOX CONNECTOR |
| ADAV |
OVERALL DIAMETER |
1.000 INCHES NOMINAL |