| TEST |
TEST DATA DOCUMENT |
81349-MIL-C-28731 SPECIFICATION |
| PRMT |
PRECIOUS MATERIAL |
GOLD |
| AFQW |
MATING END QUANTITY |
1 |
| CXCL |
INCLUDED CONTACT TYPE |
HERMAPHRODITE SINGLE MATING END SINGLE CONTACT GROUPING |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-C-28731/34 GOVERNMENT SPECIFICATION |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES |
| AEHA |
DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH |
2.282 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
1.234 INCHES NOMINAL |
| PMLC |
PRECIOUS MATERIAL AND LOCATION |
CONTACT SURFACES GOLD |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND |
| AFQZ |
CONTACT REMOVABILITY |
REMOVABLE SINGLE MATING END SINGLE CONTACT GROUPING |
| ADZC |
ENVIRONMENTAL PROTECTION |
THERMAL SHOCK RESISTANT AND HUMIDITY RESISTANT AND VIBRATION RESISTANT AND SALT WATER RESISTANT |
| AFRN |
POLARIZATION METHOD |
GUIDE PIN/SOCKET |
| CQTM |
TERMINAL LOCATION |
BACK SINGLE MATING END SINGLE CONTACT GROUPING |
| AFRC |
CONTACT MAXIMUM CURRENT RATING IN AMPS |
5.0 SINGLE MATING END SINGLE CONTACT GROUPING |
| ABMK |
OVERALL WIDTH |
2.718 INCHES NOMINAL |
| CQTZ |
CONTACT MATERIAL |
COPPER ALLOY SINGLE MATING END SINGLE CONTACT GROUPING |
| THSD |
THREAD SERIES DESIGNATOR |
UNC |
| CSCF |
TERMINAL TYPE |
CRIMP SINGLE MATING END SINGLE CONTACT GROUPING |
| ABHP |
OVERALL LENGTH |
2.770 INCHES NOMINAL |
| AAQL |
BODY STYLE |
STRAIGHT SHAPE, RECTANGULAR |
| CRBJ |
CONTACT SURFACE TREATMENT DOCUMENT AND CLASSIFICATION |
MIL-G-45204 TY II,GRADE D,CL1 MIL SPEC 1ST TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING AND QQ-N-290CL 2 FED SPEC 2ND TREATMENT RESPONSE SINGLE MATING END SINGLE CONTACT GROUPING |
| CQYH |
CONTACT SURFACE TREATMENT |
GOLD SINGLE MATING END SINGLE CONTACT GROUPING |
| AAJD |
THREAD CLASS |
2B |
| AFRV |
CONNECTOR LOCKING METHOD |
POST JACKSOCKET |
| CQZG |
INSERT MATERIAL |
PLASTIC DIALLYL PHTHALATE SINGLE MATING END |
| AFRD |
CONTACT MAXIMUM AC VOLTAGE RATING IN VOLTS |
1.000 SINGLE MATING END SINGLE CONTACT GROUPING |
| AEBW |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT |
0.765 INCHES NOMINAL |