| ABCX |
BOARD CONSTRUCTION |
SOLID CONSTRUCTION |
| ABGP |
BOARD OVERALL WIDTH |
0.750 INCHES |
| MARK |
SPECIAL MARKINGS |
1 THRU 24 |
| ABGN |
BOARD OVERALL LENGTH |
4.250 INCHES |
| ABCU |
DISTANCE BETWEEN TERMINAL ROW CENTERS |
0.250 INCHES |
| ABCS |
TERMINAL ROW QUANTITY |
2 |
| CWLG |
TERMINAL PATTERN ARRANGEMENT |
MULTI-ROW |
| MDCL |
MATERIAL DOCUMENT AND CLASSIFICATION |
MIL-P-18177,TYPE GEB MIL SPEC SINGLE MATERIAL RESPONSE BOARD |
| MATT |
MATERIAL |
GLASS FIBER BOARD AND PLASTIC EPOXY BOARD |
| ABGT |
BOARD THICKNESS |
0.090 INCHES |
| AAQL |
BODY STYLE |
STRIP TYPE |
| CRNL |
NONFEEDTHRU TERMINAL TYPE |
435 SINGLE |
| CSCS |
NONFEEDTHRU TERMINAL QUANTITY |
24 SINGLE |
| ABDX |
DISTANCE FROM LEFT EDGE OF TERMINAL BOARD TO CENTER OF FIRST MOUNTING FACILITY |
0.187 INCHES |
| CWLN |
TERMINAL DESIGN |
VERTICAL FEEDTHRU |
| CQCW |
FEEDTHRU CONNECTION END TYPE |
441 FOURTH COMBINATION BOTH ENDS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 UNTHREADED HOLE |
| ABCT |
CENTER TO CENTER DISTANCE BETWEEN TERMINALS |
0.276 INCHES |
| AAMA |
MOUNTING HOLE DIAMETER |
0.187 INCHES |
| ABDU |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.937 INCHES |
| ABDW |
DISTANCE FROM BOTTOM EDGE OF TERMINAL BOARD TO CENTER OF MOUNTING HOLE |
0.380 INCHES |