5945-00-010-5093 ( MDR142-2 , 142-2 , 927D812H63 , 927D812H63 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5945-00-010-5093 | 5945 | 000105093 | RELAY,ROTARY | 0389 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| APNR | RESET FACILITY FEATURE | NOT PROVIDED |
| CPWQ | COIL HOLD-IN DC RESISTANCE RATING | 724.000 OHMS NOMINAL |
| CPWM | WINDING CHARACTERISTIC | SINGLE WOUND UNTAPPED |
| ABKW | OVERALL HEIGHT | 4.500 INCHES NOMINAL |
| CPWL | COIL WINDING QUANTITY | 1 |
| ALGC | MOUNTING CONFIGURATION | FOUR 0.281 IN. DIA MTG HOLES ON 3.250 IN. BY 3.250 IN. MTG CENTERS |
| APAM | OPERATING CURRENT RATING | 160.000 MILLIAMPERES NOMINAL |
| APBR | DC OPERATING VOLTAGE RATING IN VOLTS | 115.000 NOMINAL |
| APNH | COIL TERMINAL QUANTITY | 2 |
| AXAZ | PULL-IN CURRENT | 160.000 MILLIAMPERES NOMINAL |
| APNG | CONTACT TERMINAL QUANTITY | 72 |
| BDFT | COIL DC RESISTANCE | 724.000 OHMS NOMINAL |
| AXBA | HOLD-IN CURRENT | 160.000 MILLIAMPERES NOMINAL |
| CPWP | COIL PULL-IN DC RESISTANCE RATING | 724.000 OHMS NOMINAL |
| BWGP | SECTION QUANTITY | 6 |
| ALXF | STRUCTURAL DESIGN | SECTIONAL |
| AYSY | ROTATION DIRECTION FOR WHICH DESIGNED | CLOCKWISE |
| ABMK | OVERALL WIDTH | 4.500 INCHES NOMINAL |
| CPWT | SHAFT ROTATION IN DEG | 22.500 |
| ABHP | OVERALL LENGTH | 5.750 INCHES NOMINAL |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| MDR142-2 | 77342 | A | 9 | 3 | X | XX | |
| 142-2 | 77342 | A | 9 | 5 | X | XX | |
| 927D812H63 | 79500 | A | 2 | 5 | X | XX | |
| 927D812H63 | 65054 | H | 9 | 5 | X | XX |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| MDR142-2 | 77342 | TYCO ELECTRONICS CORPORATION | A | A |
| 142-2 | 77342 | TYCO ELECTRONICS CORPORATION | A | A |
| 927D812H63 | 79500 | WESTINGHOUSE ELECTRIC CORP | A | A |
| 927D812H63 | 65054 | WESTINGHOUSE ELECTRIC CORP | A | H |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 1 | 01/01/1 | N | 0389 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | I | ||||
| DN | 9B----- | N | V | DISCONTINUED W/O REPLACEMENT |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | 0 | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | SMS | V | 1 | EA | 0 | U | 9B----- | N | |
| DS | SMS | V | 1 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |