| AKDX |
WINDING QUANTITY |
1 |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
150.0 DC |
| ABMK |
OVERALL WIDTH |
1.469 INCHES NOMINAL |
| ABHP |
OVERALL LENGTH |
2.219 INCHES NOMINAL |
| APCN |
COIL QUANTITY |
1 |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.125 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 WIRE HOOK ALL FUNCTIONS |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
300.0 MILLIAMPERES DC RESISTIVE LOAD |
| ABKW |
OVERALL HEIGHT |
0.906 INCHES NOMINAL |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
26.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
| CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
| CRXH |
TIME DELAY |
2.00 SECONDS NOMINAL FIXED RELEASE TIME |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
200.0 MILLIAMPERES DC SINGLE WINDING |