5945-00-189-4397 ( FC215-512 , 2T2911-12 , MIL-R-5757/23 , M5757/23-012 , B07D992BA2-0122 , M5757/23-12 )

NSN Information
NSN FSC NIIN Item Name INC
5945-00-189-4397 5945 001894397 RELAY,ELECTROMAGNETIC 3251
NSN Features
MRC Parameter Characteristics
AKDX WINDING QUANTITY 1
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
AFJN FRAGILITY FACTOR MODERATELY RUGGED
ABHP OVERALL LENGTH 1.750 INCHES MAXIMUM
ABMK OVERALL WIDTH 0.625 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE HOOK ALL FUNCTIONS
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.406 INCHES NOMINAL SINGLE MOUNTING FACILITY
APCN COIL QUANTITY 1
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-5757/23 GOVERNMENT SPECIFICATION
CBME CUBIC MEASURE 1.763 CUBIC INCHES
ABKW OVERALL HEIGHT 1.612 INCHES MAXIMUM
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 6.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
APNQ ARC QUENCHING METHOD AIR
CRXH TIME DELAY 0.015 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
ADZC ENVIRONMENTAL PROTECTION HERMETIC
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 800.0 MILLIAMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD
APNA WINDING DC RESISTANCE RATING 14.0 OHMS MINIMUM SINGLE WINDING AND 21.0 OHMS MAXIMUM SINGLE WINDING
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
ABTD MOUNTING SLOT WIDTH 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 5.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD
TEST TEST DATA DOCUMENT 81349-MIL-R-5757 SPECIFICATION
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ADTV CASE MATERIAL METAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 3.0 AMPERES AC MOTOR LOAD AND 3.0 AMPERES DC MOTOR LOAD
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
FC215-512 78290 F 1 C 5 TX
2T2911-12 02289 H 1 C 5 TX
MIL-R-5757/23 81349 M 1 4 E TX
M5757/23-012 81349 M 2 2 E TX
B07D992BA2-0122 77569 C 1 C 5 TX
M5757/23-12 81349 M 1 C AC 3 ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
FC215-512 78290 STRUTHERS-DUNN INC A F
2T2911-12 02289 HI-G CO INC A H
MIL-R-5757/23 81349 MILITARY SPECIFICATIONS A M
M5757/23-012 81349 MILITARY SPECIFICATIONS A M
B07D992BA2-0122 77569 NORTH AMERICAN PHILIPS CORP A C
M5757/23-12 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 1 03/18/1 N 8536490050 3251
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DN 9B----- N
DF N SF9EH-V F
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U N X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS Z 0 EA 0 U 9B----- N
DS SMS Z 0 EA 0 U D
DF SMS Z 0 EA 0 U SF9EH-V F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI