| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 UNTHREADED HOLE SECOND MOUNTING FACILITY |
| AKDX |
WINDING QUANTITY |
1 |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.625 INCHES NOMINAL SECOND MOUNTING FACILITY |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
25.0 AMPERES DC SINGLE WINDING |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
20.0 AMPERES DC INDUCTIVE LOAD |
| ZZZK |
SPECIFICATION/STANDARD DATA |
96906-MS25035 GOVERNMENT STANDARD |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| ABKW |
OVERALL HEIGHT |
3.218 INCHES NOMINAL |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
25.0 AMPERES AC MOTOR LOAD AND 25.0 AMPERES DC MOTOR LOAD |
| CBME |
CUBIC MEASURE |
25.737 CUBIC INCHES |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-6106 SPECIFICATION |
| APCN |
COIL QUANTITY |
1 |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.250 INCHES NOMINAL FIRST MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| TTQY |
TERMINAL TYPE AND QUANTITY |
4 SCREW ALL FUNCTIONS |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| ABMK |
OVERALL WIDTH |
2.666 INCHES MAXIMUM |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.250 INCHES NOMINAL SECOND MOUNTING FACILITY |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR FIRST MOUNTING FACILITY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| ADTV |
CASE MATERIAL |
METAL |
| ABHP |
OVERALL LENGTH |
3.000 INCHES MAXIMUM |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.173 INCHES NOMINAL FIRST MOUNTING FACILITY |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SECOND MOUNTING FACILITY |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.625 INCHES NOMINAL FIRST MOUNTING FACILITY |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.173 INCHES NOMINAL SECOND MOUNTING FACILITY |