| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| AKDX |
WINDING QUANTITY |
2 |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| ABKW |
OVERALL HEIGHT |
2.750 INCHES NOMINAL |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC AND 120.0 AC |
| ADZC |
ENVIRONMENTAL PROTECTION |
DUSTPROOF |
| ABHP |
OVERALL LENGTH |
1.750 INCHES NOMINAL |
| CRXH |
TIME DELAY |
0.500 SECONDS NOMINAL FIXED RELEASE TIME |
| APCN |
COIL QUANTITY |
1 |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 STANDARD TUBE BASE ALL FUNCTIONS |
| FEAT |
SPECIAL FEATURES |
NOMINAL OPERATING VOLTAGE 32 VDC;MIN. ADJUSTABLE PICKUP VOLTAGE RANGE28TO 40 VDC;MAX.DIFFERENTIAL SETTING8VDCMIN. DIFFERENTIAL SETTING 0.5 VDC; IN-VERSE TEMP. COMPENSATION 0.064 PORM 10PCT V. PER DEGREE F AT 77 DEG. F; REFERENCE DATA: ITEM AO11, TVR, TMC SYSTEMS AUTOMATIC DIESEL ENGINE DRIVEN ELECTRIC GENERATOR SET, BK 35, SEC 1-7, PG VI-2 |
| ABMK |
OVERALL WIDTH |
2.375 INCHES NOMINAL |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
77.0 VOLTS TEARDROP, TWO HOLES TYPE 8F ALL WINDINGS |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
| AGAV |
END ITEM IDENTIFICATION |
EG, 62.5 KVA TMC SYSTEMS |
| CRXH |
TIME DELAY |
0.0300 SECONDS NOMINAL FIXED OPERATE TIME |