5945-00-629-0326 ( 9575H2612-66 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5945-00-629-0326 | 5945 | 006290326 | RELAY,ELECTROMAGNETIC | 3251 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CRXH | TIME DELAY | 0.013 SECONDS NOMINAL FIXED RELEASE TIME |
| AKDX | WINDING QUANTITY | 1 |
| ABMK | OVERALL WIDTH | 2.406 INCHES NOMINAL |
| TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE LEAD CONTACTS |
| ABHP | OVERALL LENGTH | 3.531 INCHES NOMINAL |
| AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
| APCN | COIL QUANTITY | 1 |
| CRXH | TIME DELAY | 0.011 SECONDS NOMINAL FIXED OPERATE TIME |
| ABKW | OVERALL HEIGHT | 2.313 INCHES NOMINAL |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD ENERGIZING ELEMENT |
| APNP | DUTY TYPE | CONTINUOUS |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 120.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 12.0 AMPERES AC RESISTIVE LOAD |
| CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 600.0 AC |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 9575H2612-66 | 27192 | A | 9 | 3 | 4 | 75 |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 9575H2612-66 | 27192 | DRS POWER & CONTROL TECHNOLOGIES | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 1 | 03/12/1 | N | 8536490075 | 3251 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| GP | ------- | C | |||
| DA | Z | Q2200X- | A | ||
| DS | N | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| GP | SMS | J | 0 | EA | 0 | U | ------- | C | |
| DS | SMS | J | 0 | EA | 0 | U | D | ||
| DN | SMS | J | 0 | EA | 0 | U | 9B----- | N | |
| DA | SMS | J | 0 | EA | 0 | U | Z | Q2200X- | A |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|---|---|---|---|
| Q | 2 | 2 | 00 | X |
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |