| AKDX |
WINDING QUANTITY |
1 |
| AAJD |
THREAD CLASS |
2A SINGLE MOUNTING FACILITY |
| ABMK |
OVERALL WIDTH |
1.680 INCHES NOMINAL |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, BOTH POSITIONS MAINTAINED |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE MOUNTING FACILITY |
| AASA |
THREAD LENGTH |
0.312 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL |
| APNA |
WINDING DC RESISTANCE RATING |
2.25 KILOHMS NOMINAL SINGLE WINDING |
| APCN |
COIL QUANTITY |
1 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED STUD SINGLE MOUNTING FACILITY |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SINGLE MOUNTING FACILITY |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC RESISTIVE LOAD |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 TAB, SOLDER LUG ALL FUNCTIONS |
| ABHP |
OVERALL LENGTH |
1.840 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
1.430 INCHES NOMINAL |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC |
| APNP |
DUTY TYPE |
CONTINUOUS |