| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC |
| AKDX |
WINDING QUANTITY |
1 |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION AND 2 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 THREADED STUD ALL FUNCTIONS |
| APCN |
COIL QUANTITY |
2 |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.740 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.760 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| AGAV |
END ITEM IDENTIFICATION |
485L TACS; U-2 SUPPORT EQUIPMENT; AIRCRAFT, EAGLE F-15; AIRCRAFT, F-16; SUPPORT EQUIPMENT, OV-10A AIRCRAFT; SUPPORT EQUIPMENT, B-52 AIRCRAFT; AIRCRAFT, B-2 BOMBER (ATB); AIRCRAFT, PHANTOM F-4; AIRCRAFT, STRATOFORTRESS B-52; AIRCRAFT, F-111 |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.990 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 4.010 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| ABKW |
OVERALL HEIGHT |
3.880 INCHES NOMINAL |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.191 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.206 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
3.0 AMPERES DC RESISTIVE LOAD |
| FEAT |
SPECIAL FEATURES |
WEAPON SYSTEM ESSENTIAL |
| ABHP |
OVERALL LENGTH |
4.630 INCHES NOMINAL |
| ABMK |
OVERALL WIDTH |
3.250 INCHES NOMINAL |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
12.0 VOLTS TEARDROP, TWO HOLES TYPE 4F ALL WINDINGS |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |