| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.297 INCHES MINIMUM SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
50.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
| AKDX |
WINDING QUANTITY |
1 |
| ABHP |
OVERALL LENGTH |
3.700 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
3.305 INCHES MAXIMUM |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CRXH |
TIME DELAY |
0.03 SECONDS NOMINAL FIXED OPERATE TIME |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.250 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-6106 SPECIFICATION |
| APCN |
COIL QUANTITY |
1 |
| ZZZK |
SPECIFICATION/STANDARD DATA |
96906-MS24376 GOVERNMENT STANDARD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
50.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD |
| ABKW |
OVERALL HEIGHT |
4.475 INCHES NOMINAL |
| CBME |
CUBIC MEASURE |
54.722 CUBIC INCHES |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.687 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL OR 400.0 NOMINAL |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| TTQY |
TERMINAL TYPE AND QUANTITY |
12 THREADED STUD ALL FUNCTIONS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
| CSQC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| CRXH |
TIME DELAY |
0.065 SECONDS NOMINAL FIXED RELEASE TIME |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
750.0 MILLIAMPERES AC LAMP LOAD AND 750.0 MILLIAMPERES DC LAMP LOAD |
| CSKP |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT |
1 TWO CIRCUIT, DOUBLE BREAK/DOUBLE MAKE, ONE POSITION MOMENTARY |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
225.0 MILLIAMPERES AC SINGLE WINDING |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |