5945-01-163-3028 ( CA3-16C-10-24D-NO , CA3-16C-10-24D-NO , CA3-16C-10-24D0NO , 5253-907 , CA1-10-24VDC , CA1-10E1-24VDC , CA1-10E1 , CA3-16C-10-24D0NO )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5945-01-163-3028 | 5945 | 011633028 | RELAY,ELECTROMAGNETIC | 3251 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| AKDX | WINDING QUANTITY | 1 |
| TTQY | TERMINAL TYPE AND QUANTITY | 6 TAB, SOLDER LUG ALL FUNCTIONS |
| BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
| ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
| AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
| ABHP | OVERALL LENGTH | 1.414 INCHES NOMINAL |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
| APCN | COIL QUANTITY | 1 |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| APNQ | ARC QUENCHING METHOD | AIR |
| APNA | WINDING DC RESISTANCE RATING | 50.0 OHMS NOMINAL SINGLE WINDING |
| AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 1.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, SINGLE THROW, NORMALLY OPEN, DOUBLE MAKE, MOMENTARY ACTION |
| APNP | DUTY TYPE | CONTINUOUS |
| CBME | CUBIC MEASURE | 3.013 CUBIC INCHES |
| ABKW | OVERALL HEIGHT | 1.898 INCHES NOMINAL |
| ABTD | MOUNTING SLOT WIDTH | 0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CQYJ | MOUNTING FACILITY PATTERN | IN-LINE SINGLE MOUNTING FACILITY |
| ADTV | CASE MATERIAL | METAL |
| ABMK | OVERALL WIDTH | 1.123 INCHES NOMINAL |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 28.0 AC AND 28.0 DC |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| CA3-16C-10-24D-NO | 52034 | A | 2 | 3 | E | ZZ | |
| CA3-16C-10-24D-NO | 0SYM1 | F | 9 | 5 | 5 | ZZ | |
| CA3-16C-10-24D0NO | 4V970 | R | 9 | 5 | 5 | ZZ | |
| 5253-907 | 05869 | A | 2 | 5 | 6 | 9Z | |
| CA1-10-24VDC | 0N0T3 | A | 9 | 5 | E | TX | |
| CA1-10E1-24VDC | 0N0T3 | A | 9 | 5 | E | TX | |
| CA1-10E1 | 52034 | A | 9 | 5 | 5 | TX | |
| CA3-16C-10-24D0NO | 1SQ07 | A | 1 | C | 9F | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| CA3-16C-10-24D-NO | 52034 | SPRECHER AND SCHUH INC | A | A |
| CA3-16C-10-24D-NO | 0SYM1 | NEVADA ELECTRONICS INC | A | F |
| CA3-16C-10-24D0NO | 4V970 | HERMITAGE DISTRIBUTORS INC | A | R |
| 5253-907 | 05869 | RAYTHEON COMPANY | A | A |
| CA1-10-24VDC | 0N0T3 | MGE UPS SYSTEMS INC. | A | A |
| CA1-10E1-24VDC | 0N0T3 | MGE UPS SYSTEMS INC. | A | A |
| CA1-10E1 | 52034 | SPRECHER AND SCHUH INC | A | A |
| CA3-16C-10-24D0NO | 1SQ07 | HERMITAGE AUTOMATION & CONTROLS | F | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | X | A | 1 | 09/30/1 | N | 8536410020 | 3251 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DS | I | ||||
| DN | 9B----- | N |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | X |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | J | 0 | EA | 0 | U | D | ||
| DN | SMS | J | 0 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 061300 | X | 34410 | P | 658 | Z | 9 | A | H | Z | CIRCUIT BREAKER/SWITCH NOI |