5945-01-214-6130 ( MIL-PRF-39016/44 , MIL-R-39016/44 , M39016/44-003M )

NSN Information
NSN FSC NIIN Item Name INC
5945-01-214-6130 5945 012146130 RELAY,ELECTROMAGNETIC 3251
NSN Features
MRC Parameter Characteristics
TEST TEST DATA DOCUMENT 81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL
AKDX WINDING QUANTITY 1
BBRG STORAGE TYPE GENERAL PURPOSE WAREHOUSE
CBME CUBIC MEASURE 0.221 CUBIC INCHES
ADZC ENVIRONMENTAL PROTECTION DUSTPROOF
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.078 INCHES NOMINAL SINGLE MOUNTING FACILITY
AFJN FRAGILITY FACTOR MODERATELY RUGGED
ABTD MOUNTING SLOT WIDTH 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 0.410 INCHES MAXIMUM
ABHP OVERALL LENGTH 1.320 INCHES MAXIMUM
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 100.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD
APCN COIL QUANTITY 1
APNA WINDING DC RESISTANCE RATING 47.0 OHMS NOMINAL SINGLE WINDING
ABKW OVERALL HEIGHT 0.410 INCHES MAXIMUM
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE LEAD ALL FUNCTIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING
APNQ ARC QUENCHING METHOD AIR
CRXH TIME DELAY 0.005 SECONDS MAXIMUM FIXED RELEASE TIME
AKSL PURPOSE FOR WHICH DESIGNED GENERAL
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
ADTV CASE MATERIAL METAL
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 100.0 MILLIAMPERES DC LAMP LOAD
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 500.0 MILLIAMPERES DC INDUCTIVE LOAD
CRXH TIME DELAY 0.006 SECONDS MAXIMUM FIXED OPERATE TIME
CRTL CRITICALITY CODE JUSTIFICATION FEAT
FEAT SPECIAL FEATURES FAILURE RATE LEVEL 1.0 PERCENT
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-R-39016/44 GOVERNMENT SPECIFICATION
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
MIL-PRF-39016/44 81349 M 1 4 4 ZZ
MIL-R-39016/44 81349 M 9 5 E TX
M39016/44-003M 81349 M 2 2 E TX
Manufacturers
Part SKU Cage Manufacturer Type Status
MIL-PRF-39016/44 81349 MILITARY SPECIFICATIONS A M
MIL-R-39016/44 81349 MILITARY SPECIFICATIONS A M
M39016/44-003M 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A Y A 1 08/14/1 N 8536490050 3251
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DF N SF9EH-E F
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A N Y
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DF SMS Z 0 EA 0 U SF9EH-E F
DS SMS Z 0 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
061300 X 34410 P 658 Z 9 A H Z CIRCUIT BREAKER/SWITCH NOI