| AKDX |
WINDING QUANTITY |
1 |
| CRXH |
TIME DELAY |
0.03 SECONDS MAXIMUM FIXED OPERATE TIME |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC INDUCTIVE LOAD AND 5.0 AMPERES DC INDUCTIVE LOAD |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| ADZC |
ENVIRONMENTAL PROTECTION |
DUSTPROOF AND SHOCK RESISTANT AND VIBRATION RESISTANT |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
440.0 AC AND 28.0 DC |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.0 AMPERES AC LAMP LOAD AND 1.0 AMPERES DC LAMP LOAD |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CSKP |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT |
2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CRXH |
TIME DELAY |
0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.213 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.223 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| APCN |
COIL QUANTITY |
1 |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.0 AMPERES AC INDUCTIVE LOAD AND 50.0 AMPERES DC INDUCTIVE LOAD |
| ABKW |
OVERALL HEIGHT |
2.297 INCHES MINIMUM AND 2.485 INCHES MAXIMUM |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL OR 400.0 NOMINAL |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
| ABMK |
OVERALL WIDTH |
3.150 INCHES NOMINAL |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.240 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 3.260 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
12 THREADED STUD ALL FUNCTIONS |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
200.0 MILLIAMPERES AC SINGLE WINDING |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
12.0 AMPERES AC MOTOR LOAD AND 50.0 AMPERES DC MOTOR LOAD |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
| ABHP |
OVERALL LENGTH |
3.730 INCHES MAXIMUM |
| CSQC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.677 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 2.697 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |