| AKDX |
WINDING QUANTITY |
1 |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| ABMK |
OVERALL WIDTH |
1.025 INCHES MAXIMUM |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
115.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| AGAV |
END ITEM IDENTIFICATION |
B52G/H GB B K |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD |
| CSQJ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE |
1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
| CRXH |
TIME DELAY |
0.05 SECONDS MAXIMUM FIXED RELEASE TIME |
| CBME |
CUBIC MEASURE |
2.914 CUBIC INCHES |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-6106/13 GOVERNMENT SPECIFICATION |
| APCN |
COIL QUANTITY |
1 |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.0 AMPERES AC INDUCTIVE LOAD AND 15.0 AMPERES DC INDUCTIVE LOAD |
| CRXH |
TIME DELAY |
0.02 SECONDS MAXIMUM FIXED OPERATE TIME |
| CQYJ |
MOUNTING FACILITY PATTERN |
TRIANGLE SINGLE MOUNTING FACILITY |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 WIRE HOOK ALL FUNCTIONS |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| ABHP |
OVERALL LENGTH |
1.718 INCHES MAXIMUM |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.0 AMPERES DC INDUCTIVE LOAD |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| AJSS |
FREQUENCY IN HERTZ |
400.0 NOMINAL |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
40.0 MICROAMPERES AC SINGLE WINDING |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
500.0 MILLIAMPERES AC LAMP LOAD AND 500.0 MILLIAMPERES DC LAMP LOAD |
| ABTD |
MOUNTING SLOT WIDTH |
0.150 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ADTV |
CASE MATERIAL |
METAL |
| CSQC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| ABKW |
OVERALL HEIGHT |
1.655 INCHES MAXIMUM |
| CSKP |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 SLOTTED HOLE SINGLE MOUNTING FACILITY |