| AKDX |
WINDING QUANTITY |
1 |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
440.0 AC AND 230.0 DC |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.173 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CBME |
CUBIC MEASURE |
38.000 CUBIC INCHES |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.0 AMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
| AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL |
| APCN |
COIL QUANTITY |
1 |
| ABMK |
OVERALL WIDTH |
2.500 INCHES NOMINAL |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
133.0 MILLIAMPERES DC SINGLE WINDING |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| ABKW |
OVERALL HEIGHT |
3.125 INCHES NOMINAL |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| AGAV |
END ITEM IDENTIFICATION |
GAS TURB CNTR |
| CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
6 SCREW ALL FUNCTIONS |
| APNA |
WINDING DC RESISTANCE RATING |
180.0 OHMS NOMINAL SINGLE WINDING |
| ABHP |
OVERALL LENGTH |
4.875 INCHES NOMINAL |