| AKDX |
WINDING QUANTITY |
1 |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.5 AMPERES AC INDUCTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.5 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
| ABTD |
MOUNTING SLOT WIDTH |
0.140 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.160 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
14 WIRE HOOK ALL FUNCTIONS |
| ABKW |
OVERALL HEIGHT |
0.090 INCHES MINIMUM AND 1.010 INCHES MAXIMUM |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.615 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.635 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CRPQ |
NOMINAL OPERATING CURRENT RATING AND TYPE |
120.0 MILLIAMPERES DC SINGLE WINDING |
| CSQJ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO THE ALTITUDE OF AN ISOSCELES TRIANGLE |
1.396 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.446 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| APCN |
COIL QUANTITY |
1 |
| CQYJ |
MOUNTING FACILITY PATTERN |
TRIANGLE SINGLE MOUNTING FACILITY |
| ABHP |
OVERALL LENGTH |
1.698 INCHES MINIMUM AND 1.718 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349--83536/16 GOVERNMENT SPECIFICATION |
| FEAT |
SPECIAL FEATURES |
A81349FAILURE RATE LEVEL 1.0 PERCENT. |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-83536 SPECIFICATION SPECIFICATION |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
200.0 AC AND 28.0 DC |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| APNA |
WINDING DC RESISTANCE RATING |
290.0 OHMS NOMINAL SINGLE WINDING |
| ABMK |
OVERALL WIDTH |
1.005 INCHES MINIMUM AND 1.025 INCHES MAXIMUM |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
28.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |