| AKDX |
WINDING QUANTITY |
1 |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 THREADED HOLE SECOND MOUNTING FACILITY |
| ABMK |
OVERALL WIDTH |
3.090 INCHES MAXIMUM |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CMLP |
THREAD QUANTITY PER INCH |
32 SECOND MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
| ADZC |
ENVIRONMENTAL PROTECTION |
DUSTPROOF |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SECOND MOUNTING FACILITY |
| AJSS |
FREQUENCY IN HERTZ |
60.0 NOMINAL |
| APCN |
COIL QUANTITY |
1 |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
240.0 AC AND 30.0 DC |
| ABHP |
OVERALL LENGTH |
3.250 INCHES MAXIMUM |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
| ADTV |
CASE MATERIAL |
PLASTIC |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| AEBW |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT |
0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 SCREW ALL FUNCTIONS |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SECOND MOUNTING FACILITY |
| AAJD |
THREAD CLASS |
2B SECOND MOUNTING FACILITY |
| CWJB |
ENERGIZING ELEMENT POWER RATING |
8.0 WATTS |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR FIRST MOUNTING FACILITY |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
440.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SECOND MOUNTING FACILITY |
| CRXH |
TIME DELAY |
5.00 SECONDS MINIMUM ADJUSTABLE OPERATE TIME AND 50.00 SECONDS MAXIMUM ADJUSTABLE OPERATE TIME |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| CSKP |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| ABKW |
OVERALL HEIGHT |
4.520 INCHES MAXIMUM |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 PROBE AC RESISTIVE LOAD |
| CSQC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
480.0 AC |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SECOND MOUNTING FACILITY |
| CBME |
CUBIC MEASURE |
45.392 CUBIC INCHES |
| AEBW |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT |
0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |