| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
| CBME |
CUBIC MEASURE |
0.119 CUBIC INCHES |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AKDX |
WINDING QUANTITY |
2 |
| FEAT |
SPECIAL FEATURES |
FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| TTQY |
TERMINAL TYPE AND QUANTITY |
16 WIRE LEAD ALL FUNCTIONS |
| APCN |
COIL QUANTITY |
2 |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
6.0 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
4 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
125.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| APNA |
WINDING DC RESISTANCE RATING |
37.0 OHMS NOMINAL ALL WINDINGS |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| APNP |
DUTY TYPE |
CONTINUOUS |
| ABHP |
OVERALL LENGTH |
0.610 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-39016/35 GOVERNMENT SPECIFICATION |
| ABMK |
OVERALL WIDTH |
0.610 INCHES MAXIMUM |
| ABKW |
OVERALL HEIGHT |
0.320 INCHES MAXIMUM |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
100.0 MILLIAMPERES DC LAMP LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
500.0 MILLIAMPERES DC INDUCTIVE LOAD |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |