| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AKDX |
WINDING QUANTITY |
2 |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
26.5 VOLTS DC 25 DEG CELSIUS ALL WINDINGS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
10 PIN ALL FUNCTIONS |
| ABMK |
OVERALL WIDTH |
0.400 INCHES MAXIMUM |
| FEAT |
SPECIAL FEATURES |
FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| ABHP |
OVERALL LENGTH |
0.800 INCHES MAXIMUM |
| APCN |
COIL QUANTITY |
2 |
| CBME |
CUBIC MEASURE |
0.288 CUBIC INCHES |
| ABKW |
OVERALL HEIGHT |
0.850 INCHES MINIMUM AND 0.900 INCHES MAXIMUM |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| APNA |
WINDING DC RESISTANCE RATING |
975.0 OHMS NOMINAL ALL WINDINGS |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.115 INCHES MINIMUM FIRST MOUNTING FACILITY AND 0.130 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
150.0 MILLIAMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| CBBL |
FEATURES PROVIDED |
LATCHING CONTACTS AND POLARIZED |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE FIRST MOUNTING FACILITY |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-39016/32 GOVERNMENT SPECIFICATION |
| APNP |
DUTY TYPE |
CONTINUOUS |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-39016 SPECIFICATION |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
100.0 MILLIAMPERES AC INDUCTIVE LOAD AND 800.0 MILLIAMPERES DC INDUCTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
100.0 MILLIAMPERES DC LAMP LOAD |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.057 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.067 INCHES MAXIMUM FIRST MOUNTING FACILITY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 PLUG-IN TERMINAL SECOND MOUNTING FACILITY |