| CMLP |
THREAD QUANTITY PER INCH |
32 FIRST MOUNTING FACILITY |
| AFRG |
CONTACT MATERIAL |
SILVER |
| AKDX |
WINDING QUANTITY |
1 |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
120.0 AC |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| CMLP |
THREAD QUANTITY PER INCH |
32 SECOND MOUNTING FACILITY |
| PRMT |
PRECIOUS MATERIAL |
SILVER AND GOLD |
| ABHP |
OVERALL LENGTH |
4.312 INCHES MINIMUM AND 4.374 INCHES MAXIMUM |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SECOND MOUNTING FACILITY |
| APCN |
COIL QUANTITY |
1 |
| CRXH |
TIME DELAY |
10.00 SECONDS MAXIMUM FIXED RELEASE TIME |
| AAJD |
THREAD CLASS |
2A FIRST MOUNTING FACILITY |
| FEAT |
SPECIAL FEATURES |
8 CONTACTS ARE DRY CIRCUITS WITH THE FOLLOWING CURRENT RATINGS: 1 AMP,28.0 VDC RESISTIVE; 125 MILLIAMPS,120.0 VAC,60 HZ RESISTIVE |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
3 THREADED STUD FIRST MOUNTING FACILITY |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| APNA |
WINDING DC RESISTANCE RATING |
204.3 OHMS MINIMUM SINGLE WINDING AND 249.7 OHMS MAXIMUM SINGLE WINDING |
| CRXH |
TIME DELAY |
25.00 SECONDS MAXIMUM FIXED OPERATE TIME |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 THREADED HOLE SECOND MOUNTING FACILITY |
| CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE FIRST MOUNTING FACILITY |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND SECOND MOUNTING FACILITY |
| AAJD |
THREAD CLASS |
2B SECOND MOUNTING FACILITY |
| AAJF |
THREAD DIRECTION |
RIGHT-HAND FIRST MOUNTING FACILITY |
| THSD |
THREAD SERIES DESIGNATOR |
UNC FIRST MOUNTING FACILITY |
| PMLC |
PRECIOUS MATERIAL AND LOCATION |
CONTACTS SILVER AND CONTACT SURFACES GOLD |
| APNP |
DUTY TYPE |
CONTINUOUS |
| ABMK |
OVERALL WIDTH |
1.719 INCHES MINIMUM AND 1.781 INCHES MAXIMUM |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
16 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC RESISTIVE LOAD AND 5.0 AMPERES DC RESISTIVE LOAD |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SECOND MOUNTING FACILITY |
| ABKW |
OVERALL HEIGHT |
3.925 INCHES MINIMUM AND 4.053 INCHES MAXIMUM |
| CBME |
CUBIC MEASURE |
31.573 CUBIC INCHES |
| AGAV |
END ITEM IDENTIFICATION |
NAVY EQUIP |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES FIRST MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
50 PIN ALL FUNCTIONS |
| AFRH |
CONTACT SURFACE TREATMENT |
GOLD |