| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.0 AMPERES AC LAMP LOAD AND 2.0 AMPERES DC LAMP LOAD |
| ABHP |
OVERALL LENGTH |
1.280 INCHES MAXIMUM |
| AKDX |
WINDING QUANTITY |
1 |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.395 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.415 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| FEAT |
SPECIAL FEATURES |
FAILURE RATE 0.3 PERCENT |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 WIRE HOOK ALL FUNCTIONS |
| APCN |
COIL QUANTITY |
1 |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-6106 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |
| ABTD |
MOUNTING SLOT WIDTH |
0.123 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.143 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ABKW |
OVERALL HEIGHT |
0.810 INCHES MAXIMUM |
| ABMK |
OVERALL WIDTH |
0.640 INCHES MAXIMUM |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
8.0 AMPERES AC INDUCTIVE LOAD AND 6.0 AMPERES DC INDUCTIVE LOAD |
| CRXH |
TIME DELAY |
0.006 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| AGAV |
END ITEM IDENTIFICATION |
DEFENSPECPROG |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
28.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
4.0 AMPERES AC MOTOR LOAD AND 4.0 AMPERES DC MOTOR LOAD |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 SLOTTED HOLE SINGLE MOUNTING FACILITY |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CBME |
CUBIC MEASURE |
0.420 CUBIC INCHES |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES AC RESISTIVE LOAD AND 10.0 AMPERES DC RESISTIVE LOAD |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-6106/29 GOVERNMENT SPECIFICATION |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |