| ABHP |
OVERALL LENGTH |
1.780 INCHES NOMINAL |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AKDX |
WINDING QUANTITY |
2 |
| FEAT |
SPECIAL FEATURES |
FAILURE RATE 1.0 PERCENT PER 10,000 CYCLES |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| APCN |
COIL QUANTITY |
2 |
| CBBL |
FEATURES PROVIDED |
LATCHING CONTACTS |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
7 TERMINAL SINGLE MOUNTING FACILITY |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| ADAV |
OVERALL DIAMETER |
0.370 INCHES MAXIMUM |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
6.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
| CRXH |
TIME DELAY |
0.0015 SECONDS MAXIMUM FIXED OPERATE TIME |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
7 WIRE HOOK ALL FUNCTIONS |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-39016 SPECIFICATION |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
200.0 MILLIAMPERES DC INDUCTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
100.0 MILLIAMPERES DC LAMP LOAD |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-39016/8 GOVERNMENT SPECIFICATION |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
| APNA |
WINDING DC RESISTANCE RATING |
120.0 OHMS NOMINAL SINGLE WINDING |