| AKDX |
WINDING QUANTITY |
1 |
| CSQC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
250.0 AC |
| APNA |
WINDING DC RESISTANCE RATING |
288.0 OHMS NOMINAL SINGLE WINDING |
| BBRG |
STORAGE TYPE |
GENERAL PURPOSE WAREHOUSE |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.188 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
24.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
| ABHP |
OVERALL LENGTH |
3.500 INCHES NOMINAL |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
240.0 AC AND 28.0 DC |
| APCN |
COIL QUANTITY |
1 |
| ABMK |
OVERALL WIDTH |
2.250 INCHES NOMINAL |
| ABKW |
OVERALL HEIGHT |
2.500 INCHES NOMINAL |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
30.0 AMPERES AC RESISTIVE LOAD AND 30.0 AMPERES DC RESISTIVE LOAD |
| CWJB |
ENERGIZING ELEMENT POWER RATING |
2.0 WATTS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
20.0 AMPERES AC RESISTIVE LOAD |
| CSKP |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 SCREW ALL FUNCTIONS |
| CBME |
CUBIC MEASURE |
21.875 CUBIC INCHES |