| CBBL |
FEATURES PROVIDED |
COIL VOLTAGE SUPPRESSION AND LATCHING CONTACTS |
| AKDX |
WINDING QUANTITY |
2 |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
12.0 VOLTS TEARDROP, TWO HOLES TYPE 4F FIRST WINDING |
| APCN |
COIL QUANTITY |
2 |
| CTCN |
MINIMUM DIFFERENTIAL ELECTRICAL OPERATING RATING |
7.0 VOLTS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, TWO POSITIONS MOMENTARY |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-39016/29-058M GOVERNMENT SPECIFICATION |
| ADZC |
ENVIRONMENTAL PROTECTION |
COLD RESISTANT AND HERMETIC AND SHOCK RESISTANT AND HEAT RESISTANT AND VIBRATION RESISTANT |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| APNA |
WINDING DC RESISTANCE RATING |
500.0 OHMS NOMINAL FIRST WINDING |
| ADAV |
OVERALL DIAMETER |
0.370 INCHES MAXIMUM |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
9 PLUG-IN TERMINAL FIRST MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
9 WIRE LEAD ENERGIZING ELEMENT |
| ABKW |
OVERALL HEIGHT |
0.280 INCHES MAXIMUM |
| APNP |
DUTY TYPE |
CONTINUOUS |
| ABHP |
OVERALL LENGTH |
0.370 INCHES MAXIMUM |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-R-39016 SPECIFICATION |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |