| AKDX |
WINDING QUANTITY |
1 |
| FEAT |
SPECIAL FEATURES |
ESTABLISHED FAILURE RATE 1.0 |
| CRXH |
TIME DELAY |
0.002 SECONDS MAXIMUM FIXED OPERATE AND RELEASE TIME |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 PLUG-IN TERMINAL SINGLE MOUNTING FACILITY |
| ADAV |
OVERALL DIAMETER |
0.275 INCHES MINIMUM AND 0.335 INCHES MAXIMUM |
| AFJN |
FRAGILITY FACTOR |
MODERATELY RUGGED |
| AGAV |
END ITEM IDENTIFICATION |
AN/TPT-XCUMTE |
| APCN |
COIL QUANTITY |
1 |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
5.0 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
| APNA |
WINDING DC RESISTANCE RATING |
56.7 OHMS MINIMUM SINGLE WINDING AND 69.3 OHMS MAXIMUM SINGLE WINDING |
| AKSL |
PURPOSE FOR WHICH DESIGNED |
GENERAL |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| ABHP |
OVERALL LENGTH |
0.398 INCHES MAXIMUM |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-R-39016/7 GOVERNMENT SPECIFICATION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
5 WIRE LEAD ALL FUNCTIONS |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
200.0 MILLIAMPERES DC INDUCTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
100.0 MILLIAMPERES DC LAMP LOAD |
| CRTL |
CRITICALITY CODE JUSTIFICATION |
FEAT |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
500.0 MILLIAMPERES AC RESISTIVE LOAD AND 1.0 AMPERES DC RESISTIVE LOAD |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-39016 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL |