| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
28.0 DC |
| ABHP |
OVERALL LENGTH |
92.964 MILLIMETERS MAXIMUM |
| ADTV |
CASE MATERIAL |
STEEL, CORROSION RESISTING |
| ADZC |
ENVIRONMENTAL PROTECTION |
SHOCK RESISTANT AND HERMETIC AND HEAT RESISTANT AND VIBRATION RESISTANT |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES DC RESISTIVE LOAD |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
1 ELECTRICAL PLUG CONNECTOR SECOND MOUNTING FACILITY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
27.559 MILLIMETERS NOMINAL SECOND MOUNTING FACILITY |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE FIRST MOUNTING FACILITY |
| AJSS |
FREQUENCY IN HERTZ |
54.7 MINIMUM OR 65.5 MAXIMUM |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
31.750 MILLIMETERS NOMINAL FIRST MOUNTING FACILITY |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
5.130 MILLIMETERS MINIMUM FIRST MOUNTING FACILITY AND 5.384 MILLIMETERS MAXIMUM FIRST MOUNTING FACILITY |
| FEAT |
SPECIAL FEATURES |
MANUF.NAME, POWER MONITOR;USED TO SENSE LINE VOLTAGE,FREQUENCY AND PHASE SEQUENCE OF THREE PHASE Y POWER LINES UNDER VOLTAGE PICKUP LINE TO NEUTRAL 105 VRMS + - 2 PERCENT, OVERVOLTAGE DROP OUT LINE TO NEUTRAL 135 VRMS + - 2PERCENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
38.100 MILLIMETERS NOMINAL SECOND MOUNTING FACILITY |
| AGAV |
END ITEM IDENTIFICATION |
AN/FPS-117,RADAR SET |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
76.200 MILLIMETERS NOMINAL FIRST MOUNTING FACILITY |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR FIRST MOUNTING FACILITY |
| CRXH |
TIME DELAY |
2.00 SECONDS MAXIMUM FIXED RELEASE TIME |
| ABMK |
OVERALL WIDTH |
55.372 MILLIMETERS MAXIMUM |
| CRXH |
TIME DELAY |
4.00 SECONDS MAXIMUM FIXED OPERATE TIME |
| TTQY |
TERMINAL TYPE AND QUANTITY |
1 CONNECTOR, PLUG ALL FUNCTIONS |
| ABKW |
OVERALL HEIGHT |
91.546 MILLIMETERS MAXIMUM |