5945-01-468-2709 ( MIL-PRF-39016/6 , M39016/6-241P )

NSN Information
NSN FSC NIIN Item Name INC
5945-01-468-2709 5945 014682709 RELAY,ELECTROMAGNETIC 3251
NSN Features
MRC Parameter Characteristics
AKDX WINDING QUANTITY 1
ZZZK SPECIFICATION/STANDARD DATA 81349-MIL-PRF39016/6 GOVERNMENT SPECIFICATION
ABTD MOUNTING SLOT WIDTH 0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY
ABMK OVERALL WIDTH 0.410 INCHES MAXIMUM
ABHP OVERALL LENGTH 1.320 INCHES MAXIMUM
APCN COIL QUANTITY 1
FEAT SPECIAL FEATURES DPDT,2 AMP (RESISTIVE), HERMETICALLY SEALED, 26.5 VDC COIL, 0.1% FAILURE RATE, RAISED VERTICAL FLANGE MOUNT, RELAY
CBBL FEATURES PROVIDED POLARIZED
CSXF OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP 26.5 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING
ABKW OVERALL HEIGHT 0.410 INCHES MAXIMUM
TEST TEST DATA DOCUMENT 81349--39016 SPECIFICATION
TTQY TERMINAL TYPE AND QUANTITY 8 WIRE LEAD ALL FUNCTIONS
AXHR MOUNTING FACILITY TYPE AND QUANTITY 2 SLOTTED HOLE SINGLE MOUNTING FACILITY
CWAB MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS 115.0 AC AND 28.0 DC
APNA WINDING DC RESISTANCE RATING 700.0 OHMS NOMINAL SINGLE WINDING
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.062 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 1.078 INCHES MAXIMUM SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 2.0 AMPERES DC RESISTIVE LOAD AND 100.0 MILLIAMPERES AC RESISTIVE LOAD
ADZC ENVIRONMENTAL PROTECTION HERMETIC
APNP DUTY TYPE CONTINUOUS
CRNG NONPILE-UP MAIN CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
CQYJ MOUNTING FACILITY PATTERN IN-LINE SINGLE MOUNTING FACILITY
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 500.0 MILLIAMPERES DC INDUCTIVE LOAD
CTDL MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE 160.0 MILLIAMPERES DC LAMP LOAD
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
MIL-PRF-39016/6 81349 M 1 4 E ZZ
M39016/6-241P 81349 M 2 2 E ZZ
Manufacturers
Part SKU Cage Manufacturer Type Status
MIL-PRF-39016/6 81349 MILITARY SPECIFICATIONS A M
M39016/6-241P 81349 MILITARY SPECIFICATIONS A M
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
A 0 X A 1 10/04/1 A N 8536490050 3251
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DF N SF9EH-N F
DS N I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A A N 0 X A
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DF SMS Z 1 EA 0 U SF9EH-N F
DS SMS Z 1 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
063330 X 34400 G 72D Z 9 A H Z ELECTRICAL TERMINAL/TERMINAL BLOCKS