| AKDX |
WINDING QUANTITY |
1 |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
0.1 AMPERES DC LAMP LOAD |
| AJSS |
FREQUENCY IN HERTZ |
60.0 MINIMUM AND 400.0 MAXIMUM |
| TEST |
TEST DATA DOCUMENT |
81349-MIL-PRF-5757 SPECIFICATION |
| TTQY |
TERMINAL TYPE AND QUANTITY |
8 WIRE HOOK ALL FUNCTIONS |
| ABMK |
OVERALL WIDTH |
0.410 INCHES MAXIMUM |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.067 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APCN |
COIL QUANTITY |
1 |
| ABKW |
OVERALL HEIGHT |
1.271 INCHES NOMINAL |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.120 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CSXF |
OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP |
8.0 VOLTS TEARDROP, TWO HOLES TYPE 4F SINGLE WINDING |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
0.75 AMPERES DC INDUCTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.0 AMPERES DC RESISTIVE LOAD AND 0.3 AMPERES AC RESISTIVE LOAD |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
2 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| APNA |
WINDING DC RESISTANCE RATING |
2500.0 OHMS NOMINAL SINGLE WINDING |
| CQYJ |
MOUNTING FACILITY PATTERN |
IN-LINE SINGLE MOUNTING FACILITY |
| ABHP |
OVERALL LENGTH |
0.815 INCHES MAXIMUM |
| ZZZK |
SPECIFICATION/STANDARD DATA |
81349-MIL-PRFM-5757/13-089 GOVERNMENT SPECIFICATION |