5945-01-504-0450 ( 7022CDY2 , 7022CDY2 , PL215-005-010 REV D FN 186 , PL215-006-010 REV C FN 186 , PL215-062-010 REV D FN 186 , PL215-087-010 REV C FN 186 , PL215-088-010 REV C FN 186 , PL215-098-010 REV C FN 186 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5945-01-504-0450 | 5945 | 015040450 | RELAY,ELECTROMAGNETIC | 3251 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| CRXH | TIME DELAY | 5.00 SECONDS MINIMUM FIXED RELEASE TIME AND 50.00 SECONDS MAXIMUM FIXED RELEASE TIME |
| AKDX | WINDING QUANTITY | 1 |
| ABHP | OVERALL LENGTH | 4.520 INCHES MAXIMUM |
| AGAV | END ITEM IDENTIFICATION | MOTOR CONTROLLER |
| ABMK | OVERALL WIDTH | 2.570 INCHES MAXIMUM |
| ABKW | OVERALL HEIGHT | 2.830 INCHES MAXIMUM |
| AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
| CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 480.0 VOLTS -80 DEG FAHRENHEIT TYPE 4F SINGLE WINDING |
| APCN | COIL QUANTITY | 1 |
| CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 110.0 AC AND 30.0 DC |
| CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 15.0 AMPERES DC RESISTIVE LOAD AND 10.0 AMPERES AC RESISTIVE LOAD |
| AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.500 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| APNP | DUTY TYPE | CONTINUOUS |
| CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
| CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 7022CDY2 | 77342 | A | 2 | 3 | E | ZZ | |
| 7022CDY2 | 89020 | A | 9 | 5 | 5 | ZZ | |
| PL215-005-010 REV D FN 186 | 6Z538 | A | 2 | 5 | E | ZZ | |
| PL215-006-010 REV C FN 186 | 6Z538 | A | 2 | 5 | E | ZZ | |
| PL215-062-010 REV D FN 186 | 6Z538 | A | 2 | 5 | E | ZZ | |
| PL215-087-010 REV C FN 186 | 6Z538 | A | 2 | 5 | E | ZZ | |
| PL215-088-010 REV C FN 186 | 6Z538 | A | 2 | 5 | E | ZZ | |
| PL215-098-010 REV C FN 186 | 6Z538 | A | 2 | 5 | E | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 7022CDY2 | 77342 | TYCO ELECTRONICS CORPORATION | A | A |
| 7022CDY2 | 89020 | TYCO ELECTRONICS/AGASTAT RELAYS | A | A |
| PL215-005-010 REV D FN 186 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-006-010 REV C FN 186 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-062-010 REV D FN 186 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-087-010 REV C FN 186 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-088-010 REV C FN 186 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-098-010 REV C FN 186 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 1 | 01/16/2 | A | N | 8536490075 | 3251 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | 0 | X | A |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DN | SMS | J | 1 | EA | 0 | U | 9B----- | N | |
| DS | SMS | J | 1 | EA | 0 | U | D |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|