5945-01-504-0458 ( 6957ED104-C2ATR , PL215-007-010 REV B FN 167 , PL215-008-010 REV B FN 167 , PL215-019-010 REV B FN 167 , PL215-020-010 REV B FN 167 , PL215-021-010 REV B FN 167 , PL215-022-010 REV B FN 167 , PL215-023-010 REV B FN 167 , PL215-024-010 REV B FN 167 )
NSN Information
| NSN | FSC | NIIN | Item Name | INC |
|---|---|---|---|---|
| 5945-01-504-0458 | 5945 | 015040458 | RELAY,SOLID STATE | 3144 |
NSN Features
| MRC | Parameter | Characteristics |
|---|---|---|
| ABKW | OVERALL HEIGHT | 3.640 INCHES NOMINAL |
| AGAV | END ITEM IDENTIFICATION | MOTOR CONTROLLER |
| ABHP | OVERALL LENGTH | 4.970 INCHES NOMINAL |
| CBBL | FEATURES PROVIDED | HERMETICALLY SEALED |
| TTQY | TERMINAL TYPE AND QUANTITY | 12 SCREW |
| AMSE | VOLTAGE RATING | 440.0 VOLTS NOMINAL CONTROL |
| AFGA | OPERATING TEMP RANGE | -40.0/+50.0 DEG CELSIUS |
| FEAT | SPECIAL FEATURES | REVERSING TOP CONTROL TERMINALS |
| ABMK | OVERALL WIDTH | 2.860 INCHES NOMINAL |
| AXNP | CURRENT RATING | 72.00 AMPERES NOMINAL OVERLOAD |
Manufacturing Part Numbers (SKUs)
| Part SKU | Cage | Status | RNVC | RNCC | SADC | DAC | RNAAC |
|---|---|---|---|---|---|---|---|
| 6957ED104-C2ATR | 27192 | A | 2 | 3 | E | ZZ | |
| PL215-007-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-008-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-019-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-020-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-021-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-022-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-023-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ | |
| PL215-024-010 REV B FN 167 | 6Z538 | A | 2 | 5 | 5 | ZZ |
Manufacturers
| Part SKU | Cage | Manufacturer | Type | Status |
|---|---|---|---|---|
| 6957ED104-C2ATR | 27192 | DRS POWER & CONTROL TECHNOLOGIES | A | A |
| PL215-007-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-008-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-019-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-020-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-021-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-022-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-023-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
| PL215-024-010 REV B FN 167 | 6Z538 | CAROLINA POWER SYSTEMS OF SUMTER | A | A |
FLIS Identification
| PMIC | ADPE Code | CRITL Code | DEMIL Code | DEMIL INTG | NIIN Asgt | ESD | HMIC | ENAC | Schedule-B | INC |
|---|---|---|---|---|---|---|---|---|---|---|
| A | 0 | X | A | 1 | 01/16/2 | A | N | 3144 |
FLIS Management
| MOE | REC Rep Code | Mgmt Ctl | USC | Phrase Code | Phrase Statement |
|---|---|---|---|---|---|
| DN | 9B----- | N | |||
| DS | I |
Demilitarization Codes & Management
| DML | PMI | HMIC | ADP | CC | ESDC |
|---|---|---|---|---|---|
| A | A | N | 0 | X | A |
Miscellaneous Management
| MOE (S_A) | SOS | AAC | QUP | UI | SLC | CIIC | RC | MCC | SVC |
|---|---|---|---|---|---|---|---|---|---|
| DS | SMS | J | 1 | EA | 0 | U | D | ||
| DN | SMS | J | 1 | EA | 0 | U | 9B----- | N |
Management Control Army
| MATCAT 1 | MATCAT 2 | MATCAT 3 | MATCAT 4 5 | ARC |
|---|
Freight
| NMFC | NMFC SUB | UFC | HMC | LTL | LCL | WCC | TCC | SHC | ADC | ACC | ASH | NMF DESC |
|---|---|---|---|---|---|---|---|---|---|---|---|---|