| AKDX |
WINDING QUANTITY |
1 |
| ABKW |
OVERALL HEIGHT |
1.025 INCHES MAXIMUM |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
2.0 AMPERES AC RESISTIVE LOAD AND 2.0 AMPERES DC RESISTIVE LOAD |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
10.0 AMPERES AC MOTOR LOAD AND 10.0 AMPERES DC MOTOR LOAD |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
1.406 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
5.0 AMPERES AC LAMP LOAD AND 5.0 AMPERES DC LAMP LOAD |
| APCN |
COIL QUANTITY |
1 |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
15.0 AMPERES AC INDUCTIVE LOAD AND 12.0 AMPERES DC INDUCTIVE LOAD |
| CRNG |
NONPILE-UP MAIN CONTACT ARRANGEMENT |
3 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
0.625 INCHES NOMINAL SINGLE MOUNTING FACILITY |
| CTDL |
MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
25.0 AMPERES AC RESISTIVE LOAD AND 25.0 AMPERES DC RESISTIVE LOAD |
| AXHR |
MOUNTING FACILITY TYPE AND QUANTITY |
4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 WIRE HOOK ALL FUNCTIONS |
| CWAB |
MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| ABHP |
OVERALL LENGTH |
1.718 INCHES MAXIMUM |
| APNQ |
ARC QUENCHING METHOD |
AIR |
| AGAV |
END ITEM IDENTIFICATION |
B-52 AIRCRAFT |
| AEBV |
UNTHREADED MOUNTING HOLE DIAMETER |
0.155 INCHES MINIMUM SINGLE MOUNTING FACILITY AND 0.161 INCHES MAXIMUM SINGLE MOUNTING FACILITY |
| ADZC |
ENVIRONMENTAL PROTECTION |
HERMETIC |
| APNP |
DUTY TYPE |
CONTINUOUS |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
0.5 AMPERES AC LAMP LOAD AND 0.5 AMPERES DC LAMP LOAD |
| ABMK |
OVERALL WIDTH |
1.010 INCHES MAXIMUM |
| CSQC |
AUXILIARY CONTACT MAXIMUM VOLTAGE RATING IN VOLTS |
115.0 AC AND 28.0 DC |
| CSKP |
NONPILE-UP AUXILIARY CONTACT ARRANGEMENT |
1 POLE, DOUBLE THROW, ONE POSITION MOMENTARY |
| CQYJ |
MOUNTING FACILITY PATTERN |
RECTANGULAR SINGLE MOUNTING FACILITY |
| CWGM |
AUXILIARY CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE |
1.0 AMPERES AC INDUCTIVE LOAD AND 1.0 AMPERES DC INDUCTIVE LOAD |