| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
103.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.75 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 109.25 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 126.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CBME |
CUBIC MEASURE (NON-CORE) |
42.5 CUBIC INCHES |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO INCLOSURE AND CORE SINGLE COMPONENT |
| PKWT |
UNPACKAGED UNIT WEIGHT (NON-CORE) |
6.000 POUNDS |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| ADAT |
BODY WIDTH |
2.750 INCHES MAXIMUM |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CRBZ |
WINDING OPERATING CURRENT |
5.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| ADAU |
BODY HEIGHT |
4.500 INCHES MAXIMUM |
| AKNA |
INCLOSURE TYPE |
HERMETICALLY SEALED |
| AXGY |
MOUNTING METHOD |
THREADED STUD SINGLE GROUP |
| ADAQ |
BODY LENGTH |
3.438 INCHES MAXIMUM |
| AEHZ |
MAXIMUM OPERATING TEMP |
65.0 DEG CELSIUS |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.625 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZB |
FREQUENCY RATING |
48.0 HERTZ MINIMUM SINGLE COMPONENT AND 450.0 HERTZ MAXIMUM SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
50.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
750.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
14 TURRET |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.000 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| THSD |
THREAD SERIES DESIGNATOR |
UNF SINGLE GROUP |
| AAJD |
THREAD CLASS (NON-CORE) |
2A SINGLE GROUP |
| ABFE |
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION |
FUNGUS RESISTANT AND MOISTURE RESISTANT |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| CRBZ |
WINDING OPERATING CURRENT |
1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.190 INCHES SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |