5950-00-237-1073 ( K5331 , 42480 , 10668614 , NES-4107 )

NSN Information
NSN FSC NIIN Item Name INC
5950-00-237-1073 5950 002371073 TRANSFORMER,POWER 3249
NSN Features
MRC Parameter Characteristics
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
TEST TEST DATA DOCUMENT 18876-10668614 DRAWING
CRMJ WINDING POWER RATING 89.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT
ADAT BODY WIDTH 3.000 INCHES MAXIMUM
AAJD THREAD CLASS (NON-CORE) 2B SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 4.120 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 4.130 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CRBZ WINDING OPERATING CURRENT 24.5 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 3.2 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY
AKNA INCLOSURE TYPE FULLY INCLOSED
CRMJ WINDING POWER RATING 136.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 3.2 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY
CRBZ WINDING OPERATING CURRENT 3.2 AMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
CRMJ WINDING POWER RATING 149.6 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
AARG RELIABILITY INDICATOR NOT ESTABLISHED
AXGY MOUNTING METHOD THREADED HOLE SINGLE GROUP
CRMJ WINDING POWER RATING 149.6 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
CWJS WINDING OPERATING VOLTAGE 46.75 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY
TTQY TERMINAL TYPE AND QUANTITY 37 TAB, SOLDER LUG
ABKW OVERALL HEIGHT 4.875 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 208.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
ADAQ BODY LENGTH 6.250 INCHES MAXIMUM
CWJS WINDING OPERATING VOLTAGE 46.75 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-DELTA
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 2.245 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.255 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
AEHZ MAXIMUM OPERATING TEMP 170.0 DEG CELSIUS
CWJS WINDING OPERATING VOLTAGE 28.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 4TH SECONDARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CWJS WINDING OPERATING VOLTAGE 5.59 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY
CQJX NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 9 SECONDARY SINGLE COMPONENT
FEAT SPECIAL FEATURES ONE PRIMARY WINDING AND NINE SECONDARY WINDINGS
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
K5331 51181 A 2 5 5 TX
42480 73386 A 2 5 6 TX
10668614 18876 A 2 3 A TX
NES-4107 86632 F 1 5 6 TX
Manufacturers
Part SKU Cage Manufacturer Type Status
K5331 51181 KEYTRONICS INC. F A
42480 73386 FREED TRANSFORMER COMPANY A A
10668614 18876 U S ARMY AVIATION AND MISSILE A A
NES-4107 86632 NEWTON ENGINEERING SERVICE INC A F
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 1 10/26/1 P 3249
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DS N I
DM Z 12B2--- M
DF N SF9EH-N F
DA Z Q2200X- A V DISCONTINUED W/O REPLACEMENT
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DA SMS V 1 EA 0 U Z Q2200X- A
DS SMS J 1 EA 0 U D
DM SMS J 1 EA 0 U Z 12B2--- M
DF SMS J 1 EA 0 U SF9EH-N F
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Q 2 2 00 X
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
063420 X 35355 P 595 Z 9 A H Z TRANSFORMERS NOI LESS THAN 25 LBS