| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CRMJ |
WINDING POWER RATING |
283.7 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO SIX PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| FEAT |
SPECIAL FEATURES |
ONE PRIMARY AND ELEVEN SECONDARIES |
| CRMJ |
WINDING POWER RATING |
12.9 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CRMJ |
WINDING POWER RATING |
76.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
31.20 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 32.80 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
176.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 192.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 3RD SECONDARY |
| ABKW |
OVERALL HEIGHT |
6.500 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
21.20 AC POUNDS PER HOUR DRY SINGLE COMPONENT 4TH SECONDARY AND 22.20 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 4TH SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CRBZ |
WINDING OPERATING CURRENT |
50.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 2ND SECONDARY |
| CRMJ |
WINDING POWER RATING |
268.8 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| PKWT |
UNPACKAGED UNIT WEIGHT (NON-CORE) |
11.500 POUNDS |
| TTQY |
TERMINAL TYPE AND QUANTITY |
16 TAB, SOLDER LUG AND 49 TURRET |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
7.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 4TH SECONDARY |
| ABHP |
OVERALL LENGTH |
4.875 INCHES MAXIMUM |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 11 SECONDARY SINGLE COMPONENT |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| AXGY |
MOUNTING METHOD |
UNTHREADED HOLE SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
142.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 149.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
| ABMK |
OVERALL WIDTH |
3.125 INCHES MAXIMUM |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.500 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
WYE-DELTA-WYE |
| ABTB |
MOUNTING HOLE DIAMETER |
0.188 INCHES NOMINAL SINGLE GROUP |
| ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| AEHZ |
MAXIMUM OPERATING TEMP |
155.0 DEG CELSIUS |
| CWJS |
WINDING OPERATING VOLTAGE |
21.20 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 22.20 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
5.0 AMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY |