| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
9.40 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 9.59 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 3 PRIMARY SINGLE COMPONENT |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
WYE-WYE |
| AXGY |
MOUNTING METHOD |
BRACKET SINGLE GROUP AND SLOT SINGLE GROUP |
| CBME |
CUBIC MEASURE (NON-CORE) |
85.9 CUBIC INCHES |
| PKWT |
UNPACKAGED UNIT WEIGHT (NON-CORE) |
15.000 POUNDS |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
3.750 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| ABMK |
OVERALL WIDTH |
5.000 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
18.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 18.87 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
| ADAU |
BODY HEIGHT |
2.750 INCHES NOMINAL |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO SIX PHASE SINGLE COMPONENT |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
6.250 INCHES MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
15.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ABTD |
MOUNTING SLOT WIDTH |
0.375 INCHES NOMINAL SINGLE GROUP |
| FEAT |
SPECIAL FEATURES |
ALL CURRENTS RATED AS RECTIFIED |
| AEHZ |
MAXIMUM OPERATING TEMP |
170.0 DEG CELSIUS |
| ACZB |
FREQUENCY RATING |
380.0 HERTZ MINIMUM SINGLE COMPONENT AND 420.0 HERTZ MAXIMUM SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
18.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 18.87 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
| TTQY |
TERMINAL TYPE AND QUANTITY |
34 TAB, SOLDER LUG |
| CRBZ |
WINDING OPERATING CURRENT |
36.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
8.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
180.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 220.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |