| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 3RD SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
4.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| AAJD |
THREAD CLASS (NON-CORE) |
2B ALL GROUPINGS |
| ADAT |
BODY WIDTH |
4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
0.6 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
9.70 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| TTQY |
TERMINAL TYPE AND QUANTITY |
20 THREADED STUD |
| FEAT |
SPECIAL FEATURES |
ALL VOLTAGES ARE STATED AS OPEN CIRCUIT; ALL CURRENTS ARE STATED AS RECTIFIED; 1 PRIMARY,6 SECONDARY WINDINGS; SECONDARIES 5 & 6 ARE RATED 115VRMS |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
5.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND ALL GROUPINGS |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| AXGY |
MOUNTING METHOD |
THREADED HOLE ALL GROUPINGS |
| CQJX |
NOMINAL THREAD SIZE |
0.250 INCHES ALL GROUPINGS |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
15.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 30.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
16.80 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 33.60 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNF ALL GROUPINGS |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 6 SECONDARY SINGLE COMPONENT |
| ADAQ |
BODY LENGTH |
5.880 INCHES MINIMUM AND 6.000 INCHES MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER SINGLE COMPONENT 2ND SECONDARY AND 8.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
4.000 INCHES NOMINAL SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
| CBME |
CUBIC MEASURE (NON-CORE) |
150.0 CUBIC INCHES |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| ADAU |
BODY HEIGHT |
4.880 INCHES MINIMUM AND 5.000 INCHES MAXIMUM |
| AKPV |
MOUNTING FACILITY QUANTITY |
8 ALL GROUPINGS |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 2ND SECONDARY |
| CWJS |
WINDING OPERATING VOLTAGE |
48.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| ACZB |
FREQUENCY RATING |
47.0 HERTZ MINIMUM SINGLE COMPONENT AND 63.0 HERTZ MAXIMUM SINGLE COMPONENT |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |