| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| FEAT |
SPECIAL FEATURES |
ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
800.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 4TH SECONDARY |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| ABKW |
OVERALL HEIGHT |
2.300 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
| CRBZ |
WINDING OPERATING CURRENT |
3.0 AMPERES NOMINAL B SINGLE COMPONENT 1ST SECONDARY |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| BFMF |
COOLING METHOD |
SELF-COOLED |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
NEUTRAL TAP SINGLE COMPONENT SINGLE PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO THREE PHASE SINGLE COMPONENT AND THREE PHASE TO TWO PHASE SINGLE COMPONENT |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
| CRMJ |
WINDING POWER RATING |
90.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
| CRMJ |
WINDING POWER RATING |
90.0 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| AEHZ |
MAXIMUM OPERATING TEMP |
130.0 DEG CELSIUS |
| ABMK |
OVERALL WIDTH |
3.000 INCHES MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES NOMINAL B SINGLE COMPONENT 2ND SECONDARY |
| CRMJ |
WINDING POWER RATING |
10.0 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.138 INCHES SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 AMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY |
| ABHP |
OVERALL LENGTH |
3.500 INCHES MAXIMUM |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.960 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
7.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 4TH SECONDARY |
| ACZF |
MAXIMUM TRANSFORMER POWER RATING |
330.1 VOLT-AMPERE SINGLE COMPONENT |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
WYE-DELTA AND WYE-OPEN DELTA |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| CWJS |
WINDING OPERATING VOLTAGE |
26.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| CRMJ |
WINDING POWER RATING |
134.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.200 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
18 TAB, SOLDER LUG |