5950-00-421-8356 ( 429-5072-001 )

NSN Information
NSN FSC NIIN Item Name INC
5950-00-421-8356 5950 004218356 TRANSFORMER,POWER 3249
NSN Features
MRC Parameter Characteristics
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
ADAU BODY HEIGHT 5.500 INCHES MAXIMUM
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 50.000 POUNDS
ABTB MOUNTING HOLE DIAMETER 0.282 INCHES MINIMUM SINGLE GROUP AND 0.344 INCHES MAXIMUM SINGLE GROUP
AKNA INCLOSURE TYPE FULLY INCLOSED
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 5.365 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 5.385 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
CQLC WINDING TAP LOCATION (NON-CORE) NEUTRAL TAP SINGLE COMPONENT ALL SECONDARY
ACZD TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
CRBZ WINDING OPERATING CURRENT 2.5 AMPERES NOMINAL B AND BETTER SINGLE COMPONENT 2ND SECONDARY AND 16.3 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
CWJS WINDING OPERATING VOLTAGE 29.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY AND 34.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 8.490 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 8.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
TTQY TERMINAL TYPE AND QUANTITY 30 THREADED STUD
AEHZ MAXIMUM OPERATING TEMP 130.0 DEG CELSIUS
CWJS WINDING OPERATING VOLTAGE 200.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP THREE PHASE TO SIX PHASE SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT
CWJS WINDING OPERATING VOLTAGE 8.15 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY AND 13.20 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY
AXGY MOUNTING METHOD UNTHREADED HOLE SINGLE GROUP
ACZB FREQUENCY RATING 400.0 HERTZ NOMINAL SINGLE COMPONENT
CRMJ WINDING POWER RATING 499.8 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
CRBZ WINDING OPERATING CURRENT 2.5 AMPERES NOMINAL B AND BETTER SINGLE COMPONENT 1ST SECONDARY AND 14.7 AMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY
ADAQ BODY LENGTH 10.060 INCHES MAXIMUM
CRMJ WINDING POWER RATING 215.2 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
ADAT BODY WIDTH 7.560 INCHES MAXIMUM
Manufacturing Part Numbers (SKUs)
Part SKU Cage Status RNVC RNCC SADC DAC RNAAC
429-5072-001 97871 A 9 3 A TX
Manufacturers
Part SKU Cage Manufacturer Type Status
429-5072-001 97871 RAYTHEON COMPANY A A
FLIS Identification
PMIC ADPE Code CRITL Code DEMIL Code DEMIL INTG NIIN Asgt ESD HMIC ENAC Schedule-B INC
U X A 1 12/11/1 P 3249
FLIS Management
MOE REC Rep Code Mgmt Ctl USC Phrase Code Phrase Statement
DN 9B----- N
DS I
Demilitarization Codes & Management
DML PMI HMIC ADP CC ESDC
A U P X
Miscellaneous Management
MOE (S_A) SOS AAC QUP UI SLC CIIC RC MCC SVC
DN SMS X 1 EA 0 U 9B----- N
DS SMS X 1 EA 0 U D
Management Control Army
MATCAT 1 MATCAT 2 MATCAT 3 MATCAT 4 5 ARC
Freight
NMFC NMFC SUB UFC HMC LTL LCL WCC TCC SHC ADC ACC ASH NMF DESC
063420 X 35355 P 595 Z 9 A H Z TRANSFORMERS NOI LESS THAN 25 LBS