| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
1067.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT 1ST SECONDARY AND 1133.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 1ST SECONDARY |
| ADAT |
BODY WIDTH |
2.250 INCHES MAXIMUM |
| CRBZ |
WINDING OPERATING CURRENT |
30.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
THREE PHASE TO SINGLE PHASE SINGLE COMPONENT AND THREE PHASE TO THREE PHASE SINGLE COMPONENT |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| CWJS |
WINDING OPERATING VOLTAGE |
87.30 AC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 92.70 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY |
| ACZD |
TRANSFORMER WINDING CONNECTION TYPE |
DELTA-WYE |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.375 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
30.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 4TH SECONDARY |
| ABTB |
MOUNTING HOLE DIAMETER |
0.165 INCHES MINIMUM SINGLE GROUP AND 0.175 INCHES MAXIMUM SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
15.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 3RD SECONDARY |
| AXGY |
MOUNTING METHOD |
FLANGE SINGLE GROUP AND UNTHREADED HOLE SINGLE GROUP |
| CBME |
CUBIC MEASURE (NON-CORE) |
7.4 CUBIC INCHES |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| CWJS |
WINDING OPERATING VOLTAGE |
113.00 AC POUNDS PER HOUR DRY SINGLE COMPONENT SINGLE PRIMARY AND 195.00 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT SINGLE PRIMARY |
| CWJS |
WINDING OPERATING VOLTAGE |
87.30 AC POUNDS PER HOUR DRY SINGLE COMPONENT 4TH SECONDARY AND 92.70 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 4TH SECONDARY |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.875 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| ACZX |
WINDING SHIELDING METHOD |
INTERNAL SHIELD GROUNDED TO CORE AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
| TTQY |
TERMINAL TYPE AND QUANTITY |
14 TURRET |
| ADAU |
BODY HEIGHT |
1.160 INCHES MAXIMUM |
| CWJS |
WINDING OPERATING VOLTAGE |
1891.50 AC POUNDS PER HOUR DRY SINGLE COMPONENT 3RD SECONDARY AND 1008.50 AC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 3RD SECONDARY |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| CRBZ |
WINDING OPERATING CURRENT |
10.0 MILLIAMPERES NOMINAL B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| ADAQ |
BODY LENGTH |
2.820 INCHES MAXIMUM |
| AEHZ |
MAXIMUM OPERATING TEMP |
155.0 DEG CELSIUS |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 4 SECONDARY SINGLE COMPONENT |