| AKPV |
MOUNTING FACILITY QUANTITY |
4 SINGLE GROUP |
| TTQY |
TERMINAL TYPE AND QUANTITY |
11 STANDOFF, SOLDERLESS LUG |
| ADAT |
BODY WIDTH |
2.781 INCHES MAXIMUM |
| AAJD |
THREAD CLASS (NON-CORE) |
2B SINGLE GROUP |
| AKNA |
INCLOSURE TYPE |
FULLY INCLOSED |
| THSD |
THREAD SERIES DESIGNATOR |
UNC SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
80.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 1ST SECONDARY |
| AAJF |
THREAD DIRECTION (NON-CORE) |
RIGHT-HAND SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
12.60 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 5.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 30.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 35.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
| AARG |
RELIABILITY INDICATOR |
NOT ESTABLISHED |
| AXGY |
MOUNTING METHOD |
THREADED HOLE SINGLE GROUP |
| ABKR |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH |
1.125 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
600.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY |
| CQJX |
NOMINAL THREAD SIZE |
0.164 INCHES SINGLE GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
600.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
| ADAU |
BODY HEIGHT |
3.937 INCHES MAXIMUM |
| ADAQ |
BODY LENGTH |
2.968 INCHES MAXIMUM |
| BPLC |
WINDING FUNCTION AND QUANTITY |
1 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
CENTER TAP SINGLE COMPONENT 1ST SECONDARY |
| ACZB |
FREQUENCY RATING |
400.0 HERTZ NOMINAL SINGLE COMPONENT |
| ACZC |
INPUT-OUTPUT PHASE RELATIONSHIP |
SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
| CMLP |
THREAD QUANTITY PER INCH |
32 SINGLE GROUP |
| CRBZ |
WINDING OPERATING CURRENT |
2.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY AND 38.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY AND 4.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY AND 2.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT SINGLE PRIMARY |
| CQLC |
WINDING TAP LOCATION (NON-CORE) |
MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY |
| ABKQ |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH |
2.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
| CWJS |
WINDING OPERATING VOLTAGE |
6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |